Add to Cart
Suitable for GE-Marqutte : Pro 1000
Dash 2000/3000/4000 with option,Dash
3000/4000/5000 with Ohmeda option, Solar
8000/8000M,i/9500 with Tram Module 451/451N/851/851N,
CardioLab®/Mac-Lab®with Tram Module
451/451N;Corometrics® 120/2120 series Eagle
1000/3000/4000;Responder 3000 with option.
OEM Number; 2006644-001
OEM P/N | Part No. | Description(Cable & Connector) |
E9004GE | GA0001 | 8ft Blue Cable, Rectangular-11pin>>DB9F with tech |
![]() ![]() | ![]() |
Dash 3000/4000/5000 with o option Solar
8000/8000M, i/9500 with Tram Module
451M/851M;CardioLab®/Mac-Lab® with Tram Module
451M;Corometrics® 259;
OEM Number:2017002-003
OEM P/N | Part No. | Description(Cable & Connector) |
2017002-003 | GA0002 | 8ft Blue Cable, Rectangular-11pin>>o 6P,with o tech |
![]() |
Dash 3000/4000/5000 with o option Solar
8000/8000M, i/9500 with Tram Module
451M/851M;CardioLab®/Mac-Lab® with Tram Module
451M;Corometrics® 259
Dash 3000/4000/5000 with option
Solar 8000/8000M, i9500 with Tram module
451N5/851N5 OEM
Number:2021406-001
OEM P/N | Part No. | Description(Cable & Connector) |
2021406-001 | GA0004 | 8ft,Rectangle 11P>DB9F With Tech |
| ![]() |
TECHNICAL PARAMETERS:
LEDS | Red | 660nm normal |
Infrared | 880 / 905 / 940nm normal | |
Test Range | Oxygen Saturation(%SpO2) | 0 % to 100 % |
Pulse Rate(bpm) | 30 to 245 | |
Accuracy | SpO2 | ± 2%(90% -1 00 %) |
±3%(70%-89 %) | ||
unspecified(0-69 %) | ||
Pulse Rate | ±1 bpm(30 - 59bpm) | |
±2 bpm(60 - 149bmp) | ||
±3 bpm(150 - 245bmp) | ||
Storage and Transport Environment | - 10°C~ + 40°C | |
Operating Temperature | + 5°C~ + 40°C | |
Operating/Storage/Transportation humidity | 0% - 80% | |
Hyperbaric pressure | 86kPa - 106 kPa |
Products more details
1. Adult finger clip type spo2 sensor
Such blood oxygen probe, sensor acquires signal on adult fingers, the hard plastic shell for fixed sensors is larger and fits adult measurement, the instruments of different brand its probe shell may be slightly different, different shell shape cannot influence the performance of product.
2. Pediatric finger clip type spo2 sensor
Such blood oxygen probes, sensors in children's fingers acquisition signal, the hard plastic shell used in fixed sensor is smaller and measurements are suitable for children.
3. Adult Soft Tip type spo2 sensor./soft rubber/soft silicone tip
Such blood oxygen probe, sensor covered on adult finger to collect signals, the soft gel coat used in fixed sensors is bigger, suitable for adults. Different brands of instruments and its probe coat may be slightly different, different shape of coat cannot influence the product performance.
4. Neonatal wrap spo2 sensor or"Y" type wrap spo2 sensor.
The type of blood oxygen sensor, the sensor wrapped in neonatal acquisition signals on his foot, fixed sensors used in soft gel coat is bind package type, suitable for newborns.
![]() | ![]() |