Add to Cart
Suitable for Choice:MMED6000D/D;AnKe:553; Cheersails:CSM-2000; Goldway:UT4000; WanDong; Jumbor:JB9101/9105/9107;TianRong;BaoZhong;HongRunDa:EM-6;QiLan:M-III; JERRY:PM2000;JoyceTracker: BMD-50; Mindray:PM9000; Richer:RC9000;ShenMai:KP-900; Spurt:CP-1200; SHIPAI: KMI-1000; ZhongHengSheng:KD580; ZhongYuan: HD-2000
Choice spo2 sensor for neonate wrap for AnKe:553/Goldway:UT4000
Compatible with MMED6000D/D, AnKe:553/Goldway:UT4000/Wa nDong/TianRong/BaoZhong/QiL an:MIII/ JERRY:PM2000/Mindray:PM 9000/Richer:RC9000/ShenMai: KP-900
Choice:MMED6000D/D;AnKe:553; Biolight;Cheersails:CSM-
2000;Goldway:UT4000; WanDong;Jumbor:JB9101/9105/9107;
TianRong;BaoZhong;HongRunDa:EM-6;QiLan:MIII;
JERRY:PM2000;JoyceTracker: BMD-
50;Mindray:PM9000;Richer:RC9000;ShenMai:KP-900;
Spurt:CP-1200;SHIPAI:KMI-1000;ZhongHengSheng
:KD580; ZhongYua:HD-2000
OEM P/N | Part No. | Description(Cable & Connector) |
CCA001 | 8ft,Redel 5pin(1bit)>>DB9F, BCI | |
OEM P/N | Part No. | Description(Cable & Connector) |
CCA002 | 8ft,Redel 9pin(1bit)>>DB9F, Tech | |
TECHNICAL PARAMETERS:
LEDS | Red | 660nm normal |
Infrared | 880 / 905 / 940nm normal | |
Test Range | Oxygen Saturation(%SpO2) | 0 % to 100 % |
Pulse Rate(bpm) | 30 to 245 | |
Accuracy | SpO2 | ± 2%(90% -1 00 %) |
±3%(70%-89 %) | ||
unspecified(0-69 %) | ||
Pulse Rate | ±1 bpm(30 - 59bpm) | |
±2 bpm(60 - 149bmp) | ||
±3 bpm(150 - 245bmp) | ||
Storage and Transport Environment | - 10°C~ + 40°C | |
Operating Temperature | + 5°C~ + 40°C | |
Operating/Storage/Transportation humidity | 0% - 80% | |
Hyperbaric pressure | 86kPa - 106 kPa |
Products more details
1. Adult finger clip type spo2 sensor
Such blood oxygen probe, sensor acquires signal on adult fingers, the hard plastic shell for fixed sensors is larger and fits adult measurement, the instruments of different brand its probe shell may be slightly different, different shell shape cannot influence the performance of product.
2. Pediatric finger clip type spo2 sensor
Such blood oxygen probes, sensors in children's fingers acquisition signal, the hard plastic shell used in fixed sensor is smaller and measurements are suitable for children.
3. Adult Soft Tip type spo2 sensor./soft rubber/soft silicone tip
Such blood oxygen probe, sensor covered on adult finger to collect signals, the soft gel coat used in fixed sensors is bigger, suitable for adults. Different brands of instruments and its probe coat may be slightly different, different shape of coat cannot influence the product performance.
4. Neonatal wrap spo2 sensor or"Y" type wrap spo2 sensor.
The type of blood oxygen sensor, the sensor wrapped in neonatal acquisition signals on his foot, fixed sensors used in soft gel coat is bind package type, suitable for newborns.
![]() |